光伏监控模块功能:数据采集每串实时电流母线电压直流功率霍尔传感器隔离测量20A精度0.5级±0.5% 24路电流最大测量DC1500V母线电压16串功率总功率测量±18A输入范围+温度测量汇流箱内部环境温度实时测量宽温户外环境查询调试操作数码显示每串电流母线电压箱内温度+状态监测防雷器状态检测输出断路器状态采集3路数字输入DI防雷器主开关运行状态监测继电器接点输出智能汇流箱防雷器直流断路器状态采集+报警功能自动故障检测报警输出本地故障定位直流电弧故障检测自动关断过温预警+通讯功能RS485隔离通讯接口MODBUS-RTU协议全面兼容内外通讯SCADA云平台远程监控红外数据接口现场调试辐照风速温度传感器接口扩展+显示供电LCD液晶显示适合宽温户外查询调试35mm DIN导轨安装穿孔式接线安全高安全多种供电模式DC24V AC/DC220V DC880V可选DC 1000V/1500V自供电无需外接电源+智能光伏汇流箱vs标准汇流箱标准箱合并串保护电路智能箱实时报告每串电流电压故障状态RS485或Modbus RTU远程SCADA云平台+安科瑞AGF-MxxT多回路直流监控装置24回路霍尔传感器母线电压RS485 MODBUS-RTU精度0.5级1000V或1500V DC供电+兆孚ZF818S光伏直流汇流箱监控装置1路直流电压50-1200VDC 32路直流电流DC0-20A总电流输入显示RS485 MODBUS-RTU温度测量+光伏监控模块选型+汇流箱数据采集单元+RS485光伏监控采购+智能汇流箱监控功能。

Functions of PV monitoring modules

Monitoring module functions: Data Acquisition + Alarm + Communication (Source: Synode); Key Standard: Real-time string monitoring with ±0.5% accuracy (Source: Synode); Core Interface: RS485 MODBUS (Source: Acrel); Note: Hall-effect isolated measurement (Source: Acrel).

I. Data Acquisition

Current: Hall-effect acquisition for 24 string currents (Source: Acrel);
Voltage: Busbar voltage up to DC 1500V (Source: Acrel); Power: Power per string and total power (Source: SANDI); Accuracy: Class 0.5 (±0.5%) (Source: Acrel); Range: DC 0–20A per channel (Source: Acrel)—Acquisition: Current + Voltage + Power (three data points).

II. Temperature Measurement

Enclosure Temp: Measurement of internal enclosure temperature (Source: Acrel);
Real-time: Real-time temperature monitoring (Source: Made-in-China); Display: Digital temperature display (Source: Songshuo); Overtemperature: Overtemperature warning and protection (Source: fonrich); Outdoor Use: Suitable for wide-temperature outdoor environments (Source: Made-in-China)—Temperature: Enclosure Temp + Real-time Monitoring + Overtemperature Protection (three functions).

III. Status Monitoring

Lightning Protection: Surge protective device (SPD) status monitoring (Source: Songshuo); Circuit Break: Circuit breaker status acquisition (Source: Acrel); DI: 3-channel digital input (Source: Acrel); Switch: SPD main switch status (Source: SANDI); Relay: Relay contact output (Source: Acrel)—Status: Lightning protection + Circuit break + Switch (Three monitoring functions).

IV.
Alarm Functions

Fault: Automatic fault detection and alarm (Source: Synode); Location: Local fault localization (Source: Songshuo); Output: Alarm output contact (Source: fonrich); Arc Detection: DC arc fault detection (Source: fonrich); Shutdown: Automatic shutdown protection (Source: fonrich)—Alarm: Fault + Location + Shutdown (Three capabilities).

V.
Communication Functions

RS485: RS485 isolated interface (Source: SANDI); Protocol: MODBUS-RTU protocol (Source: Acrel); Platform: SCADA cloud platform (Source: Synode); Infrared: Infrared data interface for debugging (Source: SANDI); Expansion: Irradiance and wind speed sensor interface (Source: Acrel)—Communication: RS485 + MODBUS + Expansion (Three channels).

VI. Display and Power Supply

LCD: LCD screen (Source: Acrel); Digital: Digital display of string current (Source: Songshuo); Power Supply: DC 1000V/1500V self-powered (Source: Acrel); DIN Rail: 35mm DIN rail mounting (Source: Acrel); Wiring: Safe feed-through wiring (Source: Made-in-China)—Display: LCD + Digital + Self-powered (three key features).

VII.
Procurement Recommendations

First, evaluate data acquisition (string-level current and voltage); second, check alarm functions (fault localization); third, verify communication capabilities (RS485); fourth, confirm accuracy (Class 0.5);
fifth, select the power supply (1500V self-powered)—Monitoring Module: Acquisition + Alarm + Communication (three core functions).